{"id":28693,"date":"2021-08-11T14:15:06","date_gmt":"2021-08-11T14:15:06","guid":{"rendered":"https:\/\/blog.medel.pro\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/"},"modified":"2023-04-13T08:48:43","modified_gmt":"2023-04-13T08:48:43","slug":"las-guias-de-electrodos-de-los-implantes-cocleares-med-el","status":"publish","type":"post","link":"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/","title":{"rendered":"Las gu\u00edas de electrodos de los implantes cocleares MED-EL"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]Por sobre todas las cosas, el prop\u00f3sito de un implante coclear es crear la\u00a0<strong>mejor comunicaci\u00f3n posible<\/strong>\u00a0entre la gu\u00eda de electrodos y las delicadas estructuras neurales de la c\u00f3clea. Toda la incre\u00edble tecnolog\u00eda de nuestros implantes cocleares fluye a trav\u00e9s de este\u00a0<strong>intrincado puente<\/strong>\u00a0entre\u00a0<strong>tecnolog\u00eda y naturaleza<\/strong>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-18808\" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/download.png\" alt=\"\" width=\"1200\" height=\"224\" \/>\u00bfC\u00f3mo proporcionamos la\u00a0<strong>audici\u00f3n m\u00e1s natural<\/strong>\u00a0posible con un implante coclear? Dise\u00f1ando nuestras gu\u00edas de electrodos para que se asemejen lo m\u00e1s posible al dise\u00f1o preciso y natural de la c\u00f3clea, y su funci\u00f3n.<\/p>\n<p>Nuestras gu\u00edas de electrodos incre\u00edblemente flexibles ayudan a preservar las delicadas estructuras de la c\u00f3clea, lo que permite la\u00a0<strong>inserci\u00f3n atraum\u00e1tica por la rampa timp\u00e1nica<\/strong>\u00a0hasta la regi\u00f3n apical. Esto les permite a nuestras gu\u00edas largas de electrodos ofrecer dos vueltas enteras de cobertura coclear completa, lo cual maximiza el rango de\u00a0<strong>estimulaci\u00f3n tonot\u00f3pica natural<\/strong>.<sup>[1][2][3][4][5][6][7] <\/sup><\/p>\n<p>Finalmente, nuestra exclusiva estrategia de codificaci\u00f3n del sonido FineHearing, es la \u00fanica del mercado que utiliza dos tipos de codificaci\u00f3n de sonido para imitar tanto la estimulaci\u00f3n tonot\u00f3pica como el bloqueo de fase temporal, que sucede durante el proceso de audici\u00f3n natural, y as\u00ed obtener una calidad de sonido que ning\u00fan otro implante coclear puede igualar.<sup>[8][9][10][11][12][13]<\/sup><\/p>\n<p>En conjunto, estas tecnolog\u00edas \u00fanicas de MED-EL les permiten a nuestros electrodos proporcionar la estimulaci\u00f3n\u00a0<strong>m\u00e1s cercana a la natural <\/strong>a lo largo de toda la c\u00f3clea, para lograr los mejores resultados auditivos.<\/p>\n<p>Pero\u00a0<strong>un tama\u00f1o no se ajusta a todas las c\u00f3cleas<\/strong>, por lo cual tenemos\u00a0<strong>gu\u00edas de electrodos individualizadas<\/strong>. Al permitir una mejor correspondencia individual entre la gu\u00eda de electrodos y la c\u00f3clea, estamos acercando m\u00e1s que nunca nuestros implantes cocleares a la audici\u00f3n natural.<sup>[14][15]<\/sup><\/p>\n<ul>\n<li><span style=\"color: #c60c30;\"><strong>Preservar las estructuras cocleares:<\/strong><\/span> Nuestras incre\u00edbles<span style=\"color: #333333;\"><strong> gu\u00edas de electrodos flexibles<\/strong><\/span>\u00a0ayudan a preservar las delicadas estructuras de la c\u00f3clea, lo que permite la\u00a0inserci\u00f3n atraum\u00e1tica por la rampa timp\u00e1nica\u00a0hasta la regi\u00f3n apical.<sup>[1][2][3][4][5][6][7]<\/sup><\/li>\n<li><strong><span style=\"color: #c60c30;\">Cubrir toda la c\u00f3clea:<\/span><\/strong> Solo MED-EL ofrece gu\u00edas de electrodos lo suficientemente largas como para cubrir\u00a0<span style=\"color: #333333;\"><strong>dos espiras completas<\/strong><\/span>\u00a0de la c\u00f3clea, y obtener mejores resultados de audici\u00f3n y una calidad de sonido m\u00e1s natural.<sup>[14][15][16][17][18][19]<\/sup><\/li>\n<li><span style=\"color: #c60c30;\"><strong>Individualizar cada c\u00f3clea:<\/strong><\/span> Con nuestro completo porfolio de electrodos, puede elegir f\u00e1cilmente la gu\u00eda ideal para\u00a0<span style=\"color: #333333;\"><strong>cada c\u00f3clea<\/strong><\/span>.<sup>[14][16]<\/sup><\/li>\n<li><span style=\"color: #c60c30;\"><strong>Ambos tipos de codificaci\u00f3n del sonido natural:<\/strong> <\/span>Solo MED-EL proporciona una combinaci\u00f3n de ambos tipos de codificaci\u00f3n de sonido para obtener\u00a0<span style=\"color: #333333;\"><strong>lo m\u00e1s cercano a la percepci\u00f3n natural del sonido<\/strong><\/span>.<sup>[8][9][10][11][12][13]<\/sup><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-18801\" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/med-el-cochlear-implant-scaled.jpg\" alt=\"\" width=\"2560\" height=\"667\" \/><\/p>\n<hr \/>\n<h2><strong>Preservaci\u00f3n de las estructuras<\/strong><\/h2>\n<p>Primero, no causar da\u00f1o. Incluso en la p\u00e9rdida de la audici\u00f3n neurosensorial profunda, la c\u00f3clea est\u00e1 llena de estructuras neurales vivas<strong>; un o\u00eddo sordo no es un o\u00eddo muerto.<\/strong> Estas intrincadas estructuras neurales tienen una fracci\u00f3n del di\u00e1metro de un cabello humano, lo que hace necesarias a las gu\u00edas de electrodos ultraflexibles.<\/p>\n<p>Durante 25 a\u00f1os hemos trabajados para crear una gu\u00eda de electrodos para implantes cocleares lo <strong>m\u00e1s atraum\u00e1tica <\/strong>posible. Nuestras gu\u00edas de ajuste libre son \u00fanicas en su ingenier\u00eda y ofrecen\u00a0<strong>flexibilidad sin igual<\/strong>, lo que las convierte en las gu\u00edas de electrodos para implantes cocleares m\u00e1s atraum\u00e1ticas del mercado.<sup>[20]<\/sup><\/p>\n<p>Nuestras gu\u00edas incre\u00edblemente flexibles de pared lateral\u00a0<strong>se adaptan delicadamente<\/strong>\u00a0a la forma de cada c\u00f3clea individual para proteger las delicadas estructuras naturales. M\u00faltiples estudios recientes han demostrado que solo las gu\u00edas MED-EL permiten la inserci\u00f3n 100% por rampa timp\u00e1nica, lo cual da resultados de audici\u00f3n significativamente mejores. Nuestras delicadas gu\u00edas tambi\u00e9n son ideales en la preservaci\u00f3n de la audici\u00f3n, para una estimulaci\u00f3n electroac\u00fastica combinada.<\/p>\n<p>Nuestras gu\u00edas de ajuste libre se flexionan suavemente para adaptarse\u00a0<strong>a la forma \u00fanica de cada c\u00f3clea<\/strong>\u00a0y acercar los contactos de los electrodos a los objetivos neurales.<\/p>\n<h3>Desviaci\u00f3n de rampas<\/h3>\n<p>La base de la preservaci\u00f3n de las estructuras es la colocaci\u00f3n del electrodo\u00a0<strong>por completo en la rampa timp\u00e1nica<\/strong>. Si la gu\u00eda de electrodos se desv\u00eda hacia la rampa vestibular, la perilinfa y la endolinfa se podr\u00edan mezclar, lo que destruir\u00eda el potencial endococlear y reducir\u00eda\u00a0<strong>funciones nerviosas esenciales<\/strong>.<sup>[23][25][26][27]<\/sup><\/p>\n<div style=\"width: 760px;\" class=\"wp-video\"><video class=\"wp-video-shortcode\" id=\"video-28693-1\" width=\"760\" height=\"428\" loop autoplay preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/scala_deviation_perimodiolar_electrode_array.mp4?_=1\" \/><a href=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/scala_deviation_perimodiolar_electrode_array.mp4\">https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/scala_deviation_perimodiolar_electrode_array.mp4<\/a><\/video><\/div>\n<p>&nbsp;<\/p>\n<p>Sin embargo, la rampa timp\u00e1nica est\u00e1 separada de la rampa vestibular por estructuras incre\u00edblemente delicadas que miden solo unos pocos micros de di\u00e1metro. Las gu\u00edas precurvadas r\u00edgidas tienen m\u00e1s probabilidades de penetrar la membrana basilar y cruzar a la rampa vestibular. Este problema tambi\u00e9n existe con las gu\u00edas rectas r\u00edgidas.<sup><br \/>\n<\/sup><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-18720 \" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/2-300x257.jpg\" alt=\"Inserci\u00f3n en la escala timp\u00e1nica\" width=\"311\" height=\"265\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-18725 size-medium\" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/2.1.png-300x270.jpg\" alt=\"\" width=\"300\" height=\"270\" \/><\/p>\n<p>Solo las gu\u00edas de ajuste libre ultraflexibles de MED-EL han demostrado permitir la\u00a0<strong>colocaci\u00f3n fiable en la rampa timp\u00e1nica<\/strong>. Al flexionarse suavemente para alejarse de las estructuras delicadas, nuestras gu\u00edas FLEX permiten una inserci\u00f3n profunda atraum\u00e1tica en la c\u00f3clea sin lastimar la membrana basilar u otras estructuras neurales esenciales.<sup>[1][2][3][4][5][6][7][20]<\/sup><\/p>\n<blockquote><p><em>&#8220;Es importante que los electrodos no perforen las estructuras de la c\u00f3clea. Si el electrodo se desv\u00eda hacia la rampa vestibular, generalmente da\u00f1a la rampa media. . . el l\u00edquido en la c\u00f3clea se mezcla con el l\u00edquido que rodea las c\u00e9lulas del ganglio espiral, lo que significa que la inflamaci\u00f3n t\u00f3xica en la c\u00f3clea se extender\u00e1 al nervio&#8221;.<\/em> \u2013 Prof. Helge Rask-Andersen<\/p><\/blockquote>\n<h3><\/h3>\n<h3><\/h3>\n<h3>Inserci\u00f3n por ventana redonda<\/h3>\n<p>La ventana redonda proporciona\u00a0<strong>acceso directo<\/strong>\u00a0a la rampa timp\u00e1nica, la cual es la ruta ideal para la inserci\u00f3n atraum\u00e1tica. Esto evita el trauma potencial de la perforaci\u00f3n de una cocleostom\u00eda, as\u00ed como el riesgo de la colocaci\u00f3n por rampa vestibular.<sup>[23][27]<\/sup><\/p>\n<p>Con un di\u00e1metro basal entre 0,8 y 1,3 mm, nuestras gu\u00edas de electrodos est\u00e1n dise\u00f1adas para la inserci\u00f3n atraum\u00e1tica por ventana redonda. Y como no hay necesidad de insertar un rigidizador o una vaina en la c\u00f3clea, la perturbaci\u00f3n de las delicadas estructuras en la base de la c\u00f3clea es m\u00ednima.<\/p>\n<p><sup><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-18730 aligncenter\" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/3-1024x267.jpg\" alt=\"Inserci\u00f3n ventana redonda\" width=\"705\" height=\"184\" \/><\/sup><\/p>\n<h3>Inserci\u00f3n profunda atraum\u00e1tica<\/h3>\n<p>A medida que la c\u00f3clea se acerca al \u00e1pex, la secci\u00f3n transversal de la\u00a0<strong>rampa timp\u00e1nica se afina<\/strong>\u00a0en di\u00e1metro aproximadamente 0,7 mm a 720\u00b0. Por eso es importante asegurar que la gu\u00eda entre con seguridad en el conducto coclear. No obstante, con otras gu\u00edas delgadas, la gu\u00eda de electrodos solo cubre la espira basal, donde no es necesario un di\u00e1metro reducido.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-18735 aligncenter\" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/4.jpg\" alt=\"Inserci\u00f3n profunda atraum\u00e1tica\" width=\"374\" height=\"210\" \/><\/p>\n<p>Nuestras gu\u00edas FLEX de ajuste libre utilizan <strong>FLEXTip<\/strong>\u00a0en los 5 contactos de electrodos apicales, lo que hace de la serie FLEX, las gu\u00edas de electrodos largas y m\u00e1s delgadas del mercado. Con un di\u00e1metro de punta de 0,4 x 0,5 mm o menos, la punta <strong>FLEXTip<\/strong> se puede\u00a0<strong>colocar con seguridad y fiabilidad<\/strong>\u00a0en la\u00a0<strong>segunda espira de la rampa timp\u00e1nica<\/strong>\u00a0sin lastimar la membrana basilar.<\/p>\n<h3>Doblado de la punta<\/h3>\n<p>Con las gu\u00edas de electrodos precurvadas, la punta de la gu\u00eda de electrodos se puede incrustar y doblarse sobre s\u00ed misma. Este doblado es una complicaci\u00f3n que puede comprometer gravemente la interfaz entre los contactos del electrodo y la c\u00f3clea, y con frecuencia limita la cobertura a menos de \u00be de una espira de la c\u00f3clea.<sup>[28][29][30][31]<\/sup><\/p>\n<p>Con las gu\u00edas MED-EL, el doblado de la punta es raro; MED-EL tiene la tasa de doblado informada m\u00e1s baja.<sup>[32][33][34][35][36][37][38][29][39][40][41][42]<\/sup><\/p>\n<p>La punta FLEXTip redondeada de nuestras gu\u00edas se adapta delicadamente a la anatom\u00eda de cada c\u00f3clea individual, con lo cual existe\u00a0<strong>un riesgo muy minimizado<\/strong>\u00a0a que se incruste o se doble. En una revisi\u00f3n extensiva de m\u00e1s de 1.500 implantaciones, el doblado de la punta ocurri\u00f3 repetidamente con las gu\u00edas precurvadas y r\u00edgidas, pero no con ninguna de las m\u00e1s de 700 gu\u00edas MED-EL.<sup>[28]<\/sup><\/p>\n<h3>Preservaci\u00f3n de la audici\u00f3n<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-18750 \" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/6.jpg\" alt=\"Preservaci\u00f3n auditiva\" width=\"341\" height=\"315\" \/><\/p>\n<p>Preservar la\u00a0<strong>funci\u00f3n natural de la c\u00f3clea<\/strong>\u00a0es especialmente importante para pacientes con audici\u00f3n residual. Si una gu\u00eda se desv\u00eda hacia la rampa vestibular, es probable que toda la\u00a0<strong>audici\u00f3n residual<\/strong> se pierda permanentemente. Las gu\u00edas rectas r\u00edgidas y las precurvadas tienen muchas m\u00e1s probabilidades de causar p\u00e9rdida de la audici\u00f3n residual.<sup>[1][2][3][5][6][7][4]<\/sup><\/p>\n<p>Nuestras gu\u00edas ultraflexibles permiten una tasa superior de preservaci\u00f3n de la audici\u00f3n para\u00a0una <strong>estimulaci\u00f3n electroac\u00fastica<\/strong> combinada. La audici\u00f3n residual postoperatoria de largo plazo es un indicador \u00fatil de que la anatom\u00eda natural y la\u00a0<strong>fisiolog\u00eda de la c\u00f3clea<\/strong>\u00a0se han preservado. Esto tambi\u00e9n ofrece una base m\u00e1s intacta de las estructuras neurales para terapias futuras.<sup>[2]\u00a0[4][43][44][45]<\/sup><\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<h2><strong>Lo m\u00e1s cercano a la audici\u00f3n natural<\/strong><\/h2>\n<p>En la c\u00f3clea,\u00a0<strong>la respuesta de frecuencia natural<\/strong>\u00a0se ordena intrincadamente en una escala logar\u00edtmica a lo largo de dos espiras completas. Esta respuesta de la\u00a0<strong>frecuencia tonot\u00f3pica de lugar-tono<\/strong>\u00a0a lo largo de toda la c\u00f3clea permite un mapeo de la frecuencia por un camino claro y l\u00f3gico.<sup>[46]<\/sup><\/p>\n<p>\u00bfC\u00f3mo proporcionamos\u00a0<strong>lo m\u00e1s cercano a la audici\u00f3n natural<\/strong>\u00a0con nuestras gu\u00edas de electrodos? Alineando nuestros electrodos tan cerca como sea posible del\u00a0<strong>lugar tonot\u00f3pico natural<\/strong>\u00a0en toda la c\u00f3clea. \u00bfQu\u00e9 significa para sus pacientes la calidad de sonido m\u00e1s natural? El disfrute de la m\u00fasica m\u00e1s natural, una audici\u00f3n mucho mejor en la vida diaria, y la mejor experiencia de audici\u00f3n posible con su IC.<sup>[14][15][17][18][19]<\/sup><\/p>\n<h3>Cobertura coclear completa<\/h3>\n<p>En la audici\u00f3n natural, las fibras nerviosas del\u00a0<strong>ganglio espiral<\/strong>\u00a0est\u00e1n organizadas tonot\u00f3picamente y\u00a0<strong>se extienden por dos espiras completas<\/strong>\u00a0en la c\u00f3clea. Si el electrodo no cubre dos espiras (540-720\u00b0) de la c\u00f3clea, no puede estimular estas fibras nerviosas y no puede proporcionar una correspondencia precisa entre tono y lugar.<sup>[15]<\/sup><\/p>\n<p>Otras gu\u00edas solo cubren la espira basal de la c\u00f3clea (~360-400\u00b0), lo que limita el rango de estimulaci\u00f3n y deja la mitad de la c\u00f3clea sin usar. Solo MED-EL ofrece\u00a0<strong>gu\u00edas de electrodos largas y flexibles<\/strong>\u00a0de hasta 31,5 mm de longitud para cubrir\u00a0<strong>hasta dos espiras completas<\/strong>\u00a0(720\u00b0) de la c\u00f3clea, y alcanzar la regi\u00f3n apical.<sup>[12][47]<\/sup><\/p>\n<div style=\"width: 760px;\" class=\"wp-video\"><video class=\"wp-video-shortcode\" id=\"video-28693-2\" width=\"760\" height=\"428\" loop autoplay preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/rainbow_cochlea.mp4?_=2\" \/><a href=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/rainbow_cochlea.mp4\">https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/rainbow_cochlea.mp4<\/a><\/video><\/div>\n<h3><\/h3>\n<h3>Correspondencia tonot\u00f3pica natural<img loading=\"lazy\" decoding=\"async\" class=\"wp-image-18760 alignright\" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/8.jpg\" alt=\"\" width=\"436\" height=\"326\" \/><\/h3>\n<p>Si un electrodo cubre solo la mitad de la c\u00f3clea, las frecuencias por debajo de ~1.000 Hz no se pueden estimular en el lugar correcto, as\u00ed que estas frecuencias se mover\u00edan hacia arriba. Esto provoca una calidad del sonido poco natural, que los usuarios describen como \u201crob\u00f3tica\u201d, \u201cmet\u00e1lica\u201d, \u201ccon eco\u201d, o \u201cmec\u00e1nica\u201d. Adaptarse a este desfase entre tono y lugar puede tomar a\u00f1os, a veces solo con mejoras parciales.<sup>[10][48][49]<\/sup><\/p>\n<p>Con nuestras gu\u00edas largas que ofrecen hasta 720\u00b0 de profundidad de inserci\u00f3n angular, la gu\u00eda de electrodos se puede <strong>alinear con el mapa tonot\u00f3pico natural<\/strong>\u00a0de la membrana basilar y el ganglio espiral a lo largo de la c\u00f3clea. Esto significa que un tono a 150 Hz se puede estimular a trav\u00e9s de las mismas fibras nerviosas como un tono a 150 Hz natural, en lugar de trasponerlo artificialmente al lugar coclear tonot\u00f3pico de un tono a 1.000 Hz. Esta correspondencia de tono m\u00e1s precisa permite una experiencia de audici\u00f3n m\u00e1s natural para sus pacientes.\u00a0<sup>[8][9][10][11][15]<\/sup><\/p>\n<h3><\/h3>\n<h3><\/h3>\n<h3><\/h3>\n<h3><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-18765\" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/9-recuperado.jpg\" alt=\"\" width=\"322\" height=\"289\" \/><\/h3>\n<h3>Resultados de audici\u00f3n<\/h3>\n<p>\u00bfPor qu\u00e9 detenerse en una calidad de sonido cercana a lo natural? Al utilizar m\u00e1s del potencial coclear natural, nuestras gu\u00edas largas permiten\u00a0<strong>resultados de audici\u00f3n significativamente mejores<\/strong>. Este beneficio es especialmente \u00fatil en entornos de escucha desafiantes, como seguir una conversaci\u00f3n en un restaurante ruidoso. Tener una correspondencia m\u00e1s precisa desde el primer d\u00eda tambi\u00e9n ayuda a obtener\u00a0<strong>mejoras m\u00e1s r\u00e1pidas<\/strong>\u00a0en la habilidad para o\u00edr.<sup>[17][18][50]<\/sup><\/p>\n<h3>FineHearing: Codificaci\u00f3n natural del sonido<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-18770\" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/10.jpg\" alt=\"\" width=\"319\" height=\"311\" \/><\/p>\n<p>De manera natural, la c\u00f3clea utiliza\u00a0<strong>dos tipos de codificaci\u00f3n del sonido<\/strong>. La codificaci\u00f3n tonot\u00f3pica de lugar-tono se utiliza en todo el rango de frecuencias. Adem\u00e1s de la codificaci\u00f3n lugar-tono, los sonidos de baja frecuencia tambi\u00e9n se codifican en ese rango. Con esta codificaci\u00f3n de tiempo, las frecuencias de las se\u00f1ales nerviosas se sincronizan con las frecuencias de los sonidos por debajo de ~1000 Hz.<\/p>\n<p>Por eso creamos la \u00fanica estrategia de codificaci\u00f3n del sonido para implantes cocleares que <strong>imita la codificaci\u00f3n de tiempo natural<\/strong>\u00a0para las frecuencias bajas y proporciona\u00a0<strong>correspondencia lugar-tono<\/strong>\u00a0a lo largo de toda la c\u00f3clea. Al imitar la codificaci\u00f3n natural del sonido en cada contacto de electrodo, FineHearing proporciona calidad de sonido mucho m\u00e1s natural.<sup>[8][9][10][11]<\/sup><\/p>\n<blockquote><p><em>\u201cLas tasas de estimulaci\u00f3n basadas en el lugar, de [MED-EL], han permitido hasta ahora una restauraci\u00f3n sin igual de la percepci\u00f3n tonot\u00f3pica\u201d.<\/em>\u00a0\u2013 Rader et al. 2016<\/p><\/blockquote>\n<hr \/>\n<h2><strong>Implantes cocleares individualizados<\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-18775\" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/11.jpg\" alt=\"\" width=\"380\" height=\"374\" \/><\/p>\n<p>Cuando se trata de gu\u00eda de electrodos,\u00a0<strong>un tama\u00f1o no se ajusta a todos<\/strong>. De hecho, hay un rango de variaci\u00f3n m\u00e1s amplio en las\u00a0<strong>longitudes de los conductos cocleares<\/strong>\u00a0que en las tallas de zapatos; hasta una 50% de diferencia entre dos c\u00f3cleas. Por eso dise\u00f1amos nuestras gu\u00edas Serie FLEX para que proporcionen la longitud \u00f3ptima para el\u00a0<strong>rango completo de anatom\u00edas cocleares<\/strong>.<sup>[47][51]<\/sup><\/p>\n<p>Con cinco gu\u00edas FLEX disponibles en tama\u00f1os entre 20 y 31,5 mm, puede conseguir cobertura coclear completa e inserci\u00f3n total del electrodo en cada paciente. Y con\u00a0<strong>OTOPLAN<\/strong>, el intuitivo software de <a href=\"https:\/\/www.medel.pro\/products\/otoplan\"><strong>planificaci\u00f3n quir\u00fargica<\/strong><\/a>, puede optimizar f\u00e1cilmente la gu\u00eda de electrodos en funci\u00f3n de las medidas <strong>individuales <\/strong>de\u00a0<strong>cada c\u00f3clea<\/strong>.<\/p>\n<p>Nuestra filosof\u00eda es sencilla: Adapte el implante a su paciente, en lugar de adaptar su paciente al implante.<\/p>\n<p><em>\u201cEs una gran ventaja poder individualizar la opci\u00f3n de longitudes de electrodos. Sabemos que hay una gran variaci\u00f3n en las longitudes de las c\u00f3cleas. El \u00f3rgano de Corti, la longitud del conducto coclear var\u00eda de 25 a 36 mil\u00edmetros, esto es un cambio del 50% de un paciente a otro\u201d.<\/em>\u00a0\u2013 Prof. Paul van de Heyning<\/p>\n<h3><\/h3>\n<h3>OTOPLAN: Potente visualizaci\u00f3n<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-18780 alignleft\" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/12.jpg\" alt=\"\" width=\"361\" height=\"203\" \/><\/p>\n<p>OTOPLAN es completamente m\u00f3vil y est\u00e1 dise\u00f1ado para tablets, para que le ofrezca movilidad y flexibilidad excepcionales. Los controles t\u00e1ctiles le acercan el <strong>poder a la punta de los dedos<\/strong>. OTOPLAN le ofrece <strong>reconstrucci\u00f3n 3D incre\u00edblemente detallada<\/strong> de las estructuras anat\u00f3micas en solo segundos, inclusive del estribo y la espira basal de la c\u00f3clea. Las estructuras anat\u00f3micas principales, inclusive el <strong>nervio facial<\/strong>, la cuerda del t\u00edmpano, la cadena de huesecillos y la espira basal de la c\u00f3clea, se resaltan en la imagen 3D y en cada plano.<\/p>\n<h3><\/h3>\n<h3><\/h3>\n<h3><\/h3>\n<h3>Visibilidad \u00f3ptima de la c\u00f3clea<img loading=\"lazy\" decoding=\"async\" class=\"wp-image-18785 alignright\" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/13.jpg\" alt=\"\" width=\"338\" height=\"190\" \/><\/h3>\n<p>Con OTOPLAN, puede girar f\u00e1cilmente los planos de la imagen para encontrar la <strong>vista oblicua ideal<\/strong> de la c\u00f3clea. La visibilidad \u00f3ptima de la c\u00f3clea le permite hacer <strong>mediciones m\u00e1s precisas y consistentes<\/strong> para mejorar la calidad quir\u00fargica y la selecci\u00f3n de electrodos.<\/p>\n<p>Solo con unos clics en el flujo de trabajo guiado, puede medir con precisi\u00f3n el di\u00e1metro y la altura de la c\u00f3clea. OTOPLAN calcula al instante la longitud del conducto coclear utilizando un\u00a0<strong>preciso algoritmo<\/strong>.<\/p>\n<h3><\/h3>\n<h3>Audiograma de visualizaci\u00f3n del electrodo<\/h3>\n<h3><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-18790 \" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/14.jpg\" alt=\"\" width=\"406\" height=\"229\" \/><\/h3>\n<p>A\u00fan mejor, la visualizaci\u00f3n de electrodos de OTOPLAN le permite <strong>combinar la informaci\u00f3n anat\u00f3mica y audiol\u00f3gica<\/strong> en una vista intuitiva. Ahora, puede visualizar f\u00e1cilmente c\u00f3mo cada gu\u00eda de electrodos MED-EL se ajusta a cada c\u00f3clea.<\/p>\n<p>De hecho, puede ver\u00a0<strong>profundidad de inserci\u00f3n angular<\/strong>, frecuencia tonot\u00f3pica y % de cobertura coclear para cada contacto de electrodo en cualquier gu\u00eda, as\u00ed como la informaci\u00f3n del audiograma integrado de cada paciente. OTOPLAN hace que sea m\u00e1s f\u00e1cil que nunca elegir\u00a0la <strong>gu\u00eda de electrodos ideal para cada paciente de manera individual<\/strong>.<\/p>\n<h3><\/h3>\n<h3>Por qu\u00e9 MED-EL: Un socio de confianza<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-18822\" src=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2021\/08\/m21-scaled.jpg\" alt=\"\" width=\"2560\" height=\"804\" \/>Durante m\u00e1s de 30 a\u00f1os, MED-EL ha sido un socio de confianza y un l\u00edder en innovaci\u00f3n en implantes auditivos. Estamos aqu\u00ed para trabajar junto con usted y nos comprometemos a brindar un servicio y una asistencia excepcionales para nuestros profesionales.<\/p>\n<p>Con los sistemas de implantes cocleares m\u00e1s avanzados, ofrecemos la mejor experiencia auditiva para sus pacientes y la mejor experiencia cl\u00ednica para usted.<\/p>\n<p>&nbsp;<\/p>\n<h3>Contacto<\/h3>\n<p>\u00bfQuiere conocer m\u00e1s acerca de nuestras soluciones auditivas? <a href=\"https:\/\/www.medel.com\/latam\/about-medel\/med-el-latam\/distribuidores-y-oficinas\">Contacte a nuestro representante<\/a> correspondiente para su pa\u00eds.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong><em>Referencias:<\/em><\/strong><\/p>\n<div>\n<div class=\"sf-Long-text\">\n<div id=\"footnotesWrap\" class=\"small\"><span style=\"font-size: 10pt;\">[1] &#8211; Suhling, M.C., Majdani, O., Salcher, R., Leifholz, M., Buechner, A., Lesinksi-Scheidat, A., &amp; Lenzarz, T. (2016). The impact of electrode array length on hearing preservation in cochlear implantation. Otol Neurotol. 37(8).<\/span><br \/>\n<span style=\"font-size: 10pt;\">[2] &#8211; Helbig, S., Adel, Y., Rader, T., Stoever, T., &amp; Baumann, U. (2016). Long-term hearing preservation outcomes after cochlear implantation for electric-acoustic stimulation. Otol Neurotol. 37(9).<\/span><br \/>\n<span style=\"font-size: 10pt;\">[3] &#8211; O\u2019Connell, B.P., Hunter, J.B., Haynes, D.S., Holder, J.T., Dedmon, M.M., Noble, J.H., Dawant, B.M., Wanna, G.B. (2017). Insertion depth impacts speech perception and hearing preservation for lateral wall electrodes. Laryngoscope. 127(10).<\/span><br \/>\n<span style=\"font-size: 10pt;\">[4] &#8211; Manjaly, J.G., Nash, R., Ellis, W., Britz, A., Lavy, J.A., Shaida, A., Saeed, S.R., &amp; Khalil, S.S., (2018). Hearing preservation with standard length electrodes in pediatric cochlear implantation. Otol Neurotol. 39(9)<\/span><br \/>\n<span style=\"font-size: 10pt;\">[5] &#8211; Skarzynski, P.H., Skarzynski, H., Dziendziel, B., Rajchel, J.J., Gos, E., &amp; Lorens, A. (2019). Hearing preservation with the use of Flex20 and Flex24 electrodes in patients with partial deafness. Otol Neurotol. 40(9).<\/span><br \/>\n<span style=\"font-size: 10pt;\">[6] &#8211; Yoshimura, H., Moteki, H., Nishio, S., Miyajima, H., Miyagawa, M., &amp; Usami, S. (2020). Genetic testing has the potential to impact hearing preservation following cochlear implantation. Acta Oto-Laryngologica. 140(6)<\/span><br \/>\n<span style=\"font-size: 10pt;\">[7] &#8211; Sprinzl, G.M., Schoerg, P., Edlinger, S.H., &amp; Magele, A. (2020). Long-term hearing preservation in electric acoustic cochlear implant candidates. Otol Neurotol. 41(6)<\/span><br \/>\n<span style=\"font-size: 10pt;\">[8] &#8211; Schatzer, R., Vermeire, K., Visser, D., Krenmayr, A., Kals, M., Voormolen, M., Van de Heyning, P., &amp; Zierhofer, C. (2014). Electric-acoustic pitch comparisons in single-sided-deaf cochlear implant users: frequency-place functions and rate pitch. Hear Res., 309, 26\u201335.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[9] &#8211; Rader, T., D\u00f6ge, J., Adel, Y., Weissgerber, T., &amp; Baumann, U. (2016). Place dependent stimulation rates improve pitch perception in cochlear implantees with single-sided deafness. Hear Res., 339, 94\u2013103.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[10] &#8211; Landsberger, D.M., Vermeire, K., Claes, A., Van Rompaey, V., &amp; Van de Heyning, P. (2016). Qualities of single electrode stimulation as a function of rate and place of stimulation with a cochlear implant. Ear Hear., 37(3), 149\u2013159.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[11] &#8211; Prentiss, S., Staecker, H., &amp; Wolford, B. (2014). Ipsilateral acoustic electric pitch matching: a case study of cochlear implantation in an up-sloping hearing loss with preserved hearing across multiple frequencies. Cochlear Implants Int., 15(3), 161\u2013165.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[12] &#8211; Landsberger, D.M., Svrakic, M., Roland, J.T. Jr., &amp; Svirsky, M. (2015). The relationship between insertion angles, default frequency allocations, and spiral ganglion place pitch in cochlear implants. Ear Hear., 36(5), 207\u2013213.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[13] &#8211; Roy, A.T., Carver, C., Jiradejvong, P., &amp; Limb, C.J. (2015). Musical sound quality in cochlear implant users: A comparison in bass frequency perception between Fine Structure Processing and High-Definition Continuous Interleaved Sampling Strategies. Ear Hear., 36(5), 582\u2013590.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[14] &#8211; Canfarotta, M.W., Dillon, M.T., Buss, E., Pillsbury, H.C., Brown, K.D., &amp; O\u2019Connell, B.P. (2020). Frequency-to-Place Mismatch: Characterizing Variability and the Influence on Speech Perception Outcomes in Cochlear Implant Recipients. Ear Hear.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[15] &#8211; Li, H., Schart-Moren, N., Rohani, S., A., Ladak, H., M., Rask-Andersen, A., &amp; Agrawal, S. (2020). Synchrotron Radiation-Based Reconstruction of the Human Spiral Ganglion: Implications for Cochlear Implantation. Ear Hear. 41(1).<\/span><br \/>\n<span style=\"font-size: 10pt;\">[16] &#8211; Erixon, E., Hoegstorp, H., Wadin, K., &amp; Rask-Andersen, H. (2009). Variational Anatomy of the Human Cochlea: Implications for Cochlear Implantation. Otol Neurol. 30(1).<\/span><br \/>\n<span style=\"font-size: 10pt;\">[17] &#8211; Buechner, A., Illg, A., Majdani, O., &amp; Lenarz, T. (2017). Investigation of the effect of cochlear implant electrode length on speech comprehension in quiet and noise compared with the results with users of electro-acoustic-stimulation, a retrospective analysis. PLoS One. 12(5).<\/span><br \/>\n<span style=\"font-size: 10pt;\">[18] &#8211; Buchman, C. A., Dillon, M. T., King, E. R., Adunka, M. C., Adunka, O. F., &amp; Pillsbury, H. C. (2014). Influence of cochlear implant insertion depth on performance: a prospective randomized trial. Otol Neurotol. 35(10).<\/span><br \/>\n<span style=\"font-size: 10pt;\">[19] &#8211; Roy, A.T., Penninger, R.T., Pearl, M.S., Wuerfel, W., Jiradejvong, P., Carver, C., Buechner, A., &amp; Limb, C.J. (2016). Deeper cochlear implant electrode insertion angle improves detection of musical sound quality deterioration related to bass frequency removal. Otol Neurotol., 37(2), 146\u2013151.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[20] &#8211; Literature Search Report (2020). Data on File, MED-EL<\/span><br \/>\n<span style=\"font-size: 10pt;\">[21] &#8211; Dhanasingh, A. &amp; Jolly, C. (2017). An overview of cochlear implant electrode array designs. Hear Res. 356: 93-103.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[22] &#8211; Noble, J. H., Labadie, R. F., Gifford, R. H., &amp; Dawant, B. M. (2013). Image-guidance enables new methods for customizing cochlear implant stimulation strategies. IEEE Trans Neural Syst Rehabil Eng. 21(5).<\/span><br \/>\n<span style=\"font-size: 10pt;\">[23] &#8211; O\u2019Connell, B.P., Cakir, A., Hunter, J.B., Francis, D.O., Noble, J.H., Labadie, R.F., Zuniga, G., Dawant, B.M., Rivas, A., &amp; Wanna, G.B. (2016). Electrode location and angular insertion depth are predictors of audiologic outcomes in cochlear implantation. Otol Neurotol. 37(8):1016\u20131023.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[24] &#8211; Dhanasingh, A. &amp; Jolly, C. (2019). Review on cochlear implant electrode array tip fold-over and scalar deviation. J Otol. 14(3). 94-100.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[25] &#8211; O\u2019Connell, B.P., Hunter, J.B., &amp; Wanna, G.B., (2016). The importance of electrode location in cochlear implantation. Laryngoscope Investigative Otolaryngology, 1: 169\u2013174.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[26] &#8211; Wanna, G.B., Noble, J.H., Gifford, R.H., Dietrich, M.S., Sweeney, A.D., Zhang, D., Dawant, B.M., Rivas, A., &amp; Labadie, R.F. (2015). Impact of intrascalar electrode location, electrode type, and angular insertion depth on residual hearing in cochlear implant patients: Preliminary results. Otol Neurotol. 36(8):1343\u20131348.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[27] &#8211; Wanna, G.B., Noble, J.H., Carlson, M.L., Gifford, R.H., Dietrich, M.S., Haynes, D.S., Dawant, B.M., &amp; Labadie, R.F. (2014). Impact of electrode design and surgical approach on scalar location and cochlear implant outcomes. Laryngoscope. 124(6):1\u20137.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[28] &#8211; Gabrielpillai, J., Burck, I., Baumann, U., Stoever, T., Helbig, S. (2018). Incidence for Tip Foldover During Cochlear Implantation. Otology Neurotology, 39(9): 1115\u20131121.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[29] &#8211; McJunkin, J.,L., Durakovic, N., Herzog, J., &amp; Buchman, C.,A. (2018). Early Outcomes With a Slim, Modiolar Cochlear Implant Electrode Array. Otol Neurotol. 39(1):e28-e33.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[30] &#8211; Lang, C.P., Salcher, R., Timm, M., Teschner, M,. Lenarz, T. (2018). Tip Fold-over with the Slim Modiolar electrode (CI 532), a retrospective case series. Laryngo-Rhine-Otol. 97(S 02): S211<\/span><br \/>\n<span style=\"font-size: 10pt;\">[31] &#8211; Zuniga, M.G., Rivas, A., Hedley-Williams, A., Gifford, R.H., Dwyer, R., Dawant, B.M., Sunderhaus, L.W., Hovis, K.L., Wanna, G.B., Noble, J.H., &amp; Labadie, R.F. (2016). Tip fold-over in cochlear implantation: Case series. Otol Neurotol. 38(2):199\u2013206.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[32] &#8211; Aschendorff, A., Briggs, R., Brademann, G., Helbig, S., Hornung, J., Lenarz, T., Marx, M., Ramos, A., Stoever, T., Escude, B., &amp; James, C.J. (2017). Clinical investigation of the Nucleus Slim Modiolar Electrode. Audiol Neurootol. 22(3). 169\u2013179<\/span><br \/>\n<span style=\"font-size: 10pt;\">[33] &#8211; Cosetti, M.K., Troob, S.H., Latzman, J.M., Shapiro, W.H., Roland, J.T., &amp; Waltzman, S.B. (2012). An evidence-based algorithm for intraoperative monitoring during cochlear implantation. Otol Neurotol. 33(2). 169\u2013176.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[34] &#8211; Friedmann, D.R., Kamen, E., Choudhury, B., &amp; Roland, J.T. (2019). Surgical experience and early outcomes with a slim perimodiolar electrode. Otol Neurotol. 40(3).<\/span><br \/>\n<span style=\"font-size: 10pt;\">[35] &#8211; Gabrielpillai, J., Burck, I., Baumann, U., Stoever, T., Helbig, S. (2018). Incidence for Tip Foldover During Cochlear Implantation. Otology Neurotology, 39(9): 1115\u20131121. ID 12 Gomez Serrano, et al (2019)<\/span><br \/>\n<span style=\"font-size: 10pt;\">[36] &#8211; Grolman, W., Maat, A., Verdam, F., Simis, Y., Carelson, B., Freling, N., &amp; Tange, R.A. (2009). Spread of excitation measurements for the detection of electrode array foldovers: A prospective study comparing 3-dimensional rotational x-ray and intraoperative spread of excitation measurements. Otol Neurotol. 30(1).27\u201333.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[37] &#8211; Jia, H., Torres, R., Nguyen, Y., De Seta, D., Ferrary, E., Wu, H., Sterkers, O., Bernardschi, D., &amp; Mosnier, I. (2018). Intraoperative conebeam CT for assessment of intracochlear positioning of electrode arrays in adult recipients of cochlear implants. AJNR Am J Neuroradiol. 39(4). 768\u2013774.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[38] &#8211; Lohmann, A.R., Carlson, M.L., &amp; Sladen, D.P. (2018). Intraoperative cochlear implant device testing utilizing an automated remote system: A prospective pilot study. Otol Neurotol. 39(3). 313\u2013317.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[39] &#8211; Sipari, S., Iso-Mustajarvi, M., Lopponen, H., &amp; Dietz, A. (2018). The insertion results of a Mid-Scala electrode assessed by MRI and CBCT image fusion. Otol Neurotol. 39(10).<\/span><br \/>\n<span style=\"font-size: 10pt;\">[40] &#8211; Stefanescu, E.H. &amp; Motoi, S. (2018). Selection of the appropriate cochlear electrode array using a specifically developed research software application. J Laryngol Otol. 132(6). 544\u2013549.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[41] &#8211; Timm, M.E., Majdani, O., Weller, T., Windeler, M., Lenarz, T., Buechner, A. &amp; Salcher, R.B. (2018). Patient specific selection of lateral wall cochlear implant electrodes based on anatomical indication ranges. PLoS ONE 13(10).<\/span><br \/>\n<span style=\"font-size: 10pt;\">[42] &#8211; Mittmann, P., Lauer, G., Ernst, A., Mutze, S., Hassepass, F., Arndt, S., Arweiler-Harbeck, D., &amp; Christov, F. (2020). Electrophysiological detection of electrode fold over in perimodiolar cochlear implant electrode arrays: a multi center study case series. Eur Arch Otorhinolaryngol. 277(1). 31\u201335.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[43] &#8211; US Food &amp; Drug Administration. (2016). Premarket approval, MED-EL, MED-EL EAS System. P000025\/S084.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[44] &#8211; US Food &amp; Drug Administration. (2014). Premarket Approval, Cochlear Americas, Nucleus Hybrid L24 cochlear implant system. P130016.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[45] &#8211; Nassiri, A.M., Yawn, R.J., Gifford, R. H., Haynes, D.S., Roberts, J.B., Gilbane, M.S., Murfee, J., &amp; Bennett, M.L. (2019). Intraoperative electrically evoked compound action potential (ECAP) measurements in traditional and hearing preservation cochlear implantation. J Am Acad Audiol. 30(10). 918\u00ac\u2013926.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[46] &#8211; Greenwood, D.D. (1990). A cochlear frequency-position function for several species\u201329 years later. J Acoust Soc Am., 87(6), 2592\u20132605.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[47] &#8211; Analysis based on mean cochlear values and clinical data. Data on file.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[48] &#8211; McDermott, H., Sucher, C., &amp; Simpson, A. (2009). Electro-acoustic stimulation. Acoustic and electric pitch comparisons. Audiol Neurootol., 14(1), 2\u20137.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[49] &#8211; Harris, R.L., Gibson, W.P. Johnson, M., Brew, J., Bray, M., &amp; Psarros, C. (2011). Intra-individual assessment of speech and music perception in cochlear implant users with contralateral Cochlear and MED-EL systems. Acta Otolaryngol., 131(12), 1270\u20131278.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[50] &#8211; Buss, E., Dillon, M.T., Rooth, M.A., King, E.R., Deres, E.J., Buchman, C.A., Pillsbury, H.C., &amp; Brown, K.D. (2018). Effect of cochlear implantation on binaural hearing in adults with unilateral hearing loss. Trends Hear. 22.<\/span><br \/>\n<span style=\"font-size: 10pt;\">[51] &#8211; Timm, M.E., Majdani, O., Weller, T., Windeler, M., Lenarz, T., Buechner, A. &amp; Salcher, R.B. (2018). Patient specific selection of lateral wall cochlear implant electrodes based on anatomical indication ranges. PLoS ONE 13(10)<\/span><\/div>\n<\/div>\n<\/div>\n<div>\n<div class=\"sf-Long-text\">\n<p class=\"small\"><span style=\"font-size: 10pt;\"><em>* OTOPLAN es un producto de CAScination AG<\/em><\/span>.<\/p>\n<\/div>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text]Por sobre todas las cosas, el prop\u00f3sito de un implante coclear es crear la\u00a0mejor comunicaci\u00f3n posible\u00a0entre la gu\u00eda de electrodos y las delicadas estructuras neurales de la c\u00f3clea. Toda la incre\u00edble tecnolog\u00eda de nuestros implantes cocleares fluye a trav\u00e9s de este\u00a0intrincado puente\u00a0entre\u00a0tecnolog\u00eda y naturaleza. \u00bfC\u00f3mo proporcionamos la\u00a0audici\u00f3n m\u00e1s natural\u00a0posible con un implante coclear? Dise\u00f1ando nuestras [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":28056,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2554,2552],"tags":[],"class_list":["post-28693","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-productos-y-actualizaciones-latam","category-quirurgico"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Las gu\u00edas de electrodos de los implantes cocleares MED-EL - Blog para Profesionales<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Las gu\u00edas de electrodos de los implantes cocleares MED-EL - Blog para Profesionales\" \/>\n<meta property=\"og:description\" content=\"[vc_row][vc_column][vc_column_text]Por sobre todas las cosas, el prop\u00f3sito de un implante coclear es crear la\u00a0mejor comunicaci\u00f3n posible\u00a0entre la gu\u00eda de electrodos y las delicadas estructuras neurales de la c\u00f3clea. Toda la incre\u00edble tecnolog\u00eda de nuestros implantes cocleares fluye a trav\u00e9s de este\u00a0intrincado puente\u00a0entre\u00a0tecnolog\u00eda y naturaleza. \u00bfC\u00f3mo proporcionamos la\u00a0audici\u00f3n m\u00e1s natural\u00a0posible con un implante coclear? Dise\u00f1ando nuestras [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/\" \/>\n<meta property=\"og:site_name\" content=\"MED-EL Professionals Blog\" \/>\n<meta property=\"article:published_time\" content=\"2021-08-11T14:15:06+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-04-13T08:48:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2023\/02\/electrode_manufacturing_hand03-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1501\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"MED-EL\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@medel\" \/>\n<meta name=\"twitter:site\" content=\"@medel\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"MED-EL\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"21 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/\"},\"author\":{\"name\":\"MED-EL\",\"@id\":\"https:\/\/blog.medel.pro\/de\/#\/schema\/person\/b81eab3e22287063f6f0d9e2499d0f02\"},\"headline\":\"Las gu\u00edas de electrodos de los implantes cocleares MED-EL\",\"datePublished\":\"2021-08-11T14:15:06+00:00\",\"dateModified\":\"2023-04-13T08:48:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/\"},\"wordCount\":4391,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/blog.medel.pro\/de\/#organization\"},\"image\":{\"@id\":\"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2023\/02\/electrode_manufacturing_hand03-1.jpg\",\"articleSection\":[\"PRODUCTOS Y ACTUALIZACIONES\",\"Quir\u00fargico\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/\",\"url\":\"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/\",\"name\":\"Las gu\u00edas de electrodos de los implantes cocleares MED-EL - Blog para Profesionales\",\"isPartOf\":{\"@id\":\"https:\/\/blog.medel.pro\/de\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2023\/02\/electrode_manufacturing_hand03-1.jpg\",\"datePublished\":\"2021-08-11T14:15:06+00:00\",\"dateModified\":\"2023-04-13T08:48:43+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#primaryimage\",\"url\":\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2023\/02\/electrode_manufacturing_hand03-1.jpg\",\"contentUrl\":\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2023\/02\/electrode_manufacturing_hand03-1.jpg\",\"width\":1501,\"height\":1080},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.medel.pro\/latam\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Las gu\u00edas de electrodos de los implantes cocleares MED-EL\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.medel.pro\/de\/#website\",\"url\":\"https:\/\/blog.medel.pro\/de\/\",\"name\":\"MED-EL Professionals Blog\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/blog.medel.pro\/de\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.medel.pro\/de\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/blog.medel.pro\/de\/#organization\",\"name\":\"MED-EL Professionals Blog\",\"url\":\"https:\/\/blog.medel.pro\/de\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/blog.medel.pro\/de\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2023\/05\/MED-EL_RGB_Red_Symbol.jpg\",\"contentUrl\":\"https:\/\/blog.medel.pro\/wp-content\/uploads\/2023\/05\/MED-EL_RGB_Red_Symbol.jpg\",\"width\":200,\"height\":200,\"caption\":\"MED-EL Professionals Blog\"},\"image\":{\"@id\":\"https:\/\/blog.medel.pro\/de\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/x.com\/medel\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.medel.pro\/de\/#\/schema\/person\/b81eab3e22287063f6f0d9e2499d0f02\",\"name\":\"MED-EL\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Las gu\u00edas de electrodos de los implantes cocleares MED-EL - Blog para Profesionales","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/","og_locale":"es_ES","og_type":"article","og_title":"Las gu\u00edas de electrodos de los implantes cocleares MED-EL - Blog para Profesionales","og_description":"[vc_row][vc_column][vc_column_text]Por sobre todas las cosas, el prop\u00f3sito de un implante coclear es crear la\u00a0mejor comunicaci\u00f3n posible\u00a0entre la gu\u00eda de electrodos y las delicadas estructuras neurales de la c\u00f3clea. Toda la incre\u00edble tecnolog\u00eda de nuestros implantes cocleares fluye a trav\u00e9s de este\u00a0intrincado puente\u00a0entre\u00a0tecnolog\u00eda y naturaleza. \u00bfC\u00f3mo proporcionamos la\u00a0audici\u00f3n m\u00e1s natural\u00a0posible con un implante coclear? Dise\u00f1ando nuestras [&hellip;]","og_url":"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/","og_site_name":"MED-EL Professionals Blog","article_published_time":"2021-08-11T14:15:06+00:00","article_modified_time":"2023-04-13T08:48:43+00:00","og_image":[{"width":1501,"height":1080,"url":"https:\/\/blog.medel.pro\/wp-content\/uploads\/2023\/02\/electrode_manufacturing_hand03-1.jpg","type":"image\/jpeg"}],"author":"MED-EL","twitter_card":"summary_large_image","twitter_creator":"@medel","twitter_site":"@medel","twitter_misc":{"Written by":"MED-EL","Est. reading time":"21 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#article","isPartOf":{"@id":"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/"},"author":{"name":"MED-EL","@id":"https:\/\/blog.medel.pro\/de\/#\/schema\/person\/b81eab3e22287063f6f0d9e2499d0f02"},"headline":"Las gu\u00edas de electrodos de los implantes cocleares MED-EL","datePublished":"2021-08-11T14:15:06+00:00","dateModified":"2023-04-13T08:48:43+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/"},"wordCount":4391,"commentCount":0,"publisher":{"@id":"https:\/\/blog.medel.pro\/de\/#organization"},"image":{"@id":"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.medel.pro\/wp-content\/uploads\/2023\/02\/electrode_manufacturing_hand03-1.jpg","articleSection":["PRODUCTOS Y ACTUALIZACIONES","Quir\u00fargico"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/","url":"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/","name":"Las gu\u00edas de electrodos de los implantes cocleares MED-EL - Blog para Profesionales","isPartOf":{"@id":"https:\/\/blog.medel.pro\/de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#primaryimage"},"image":{"@id":"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.medel.pro\/wp-content\/uploads\/2023\/02\/electrode_manufacturing_hand03-1.jpg","datePublished":"2021-08-11T14:15:06+00:00","dateModified":"2023-04-13T08:48:43+00:00","breadcrumb":{"@id":"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#primaryimage","url":"https:\/\/blog.medel.pro\/wp-content\/uploads\/2023\/02\/electrode_manufacturing_hand03-1.jpg","contentUrl":"https:\/\/blog.medel.pro\/wp-content\/uploads\/2023\/02\/electrode_manufacturing_hand03-1.jpg","width":1501,"height":1080},{"@type":"BreadcrumbList","@id":"https:\/\/blog.medel.pro\/latam\/productos-y-actualizaciones-latam\/las-guias-de-electrodos-de-los-implantes-cocleares-med-el\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.medel.pro\/latam\/"},{"@type":"ListItem","position":2,"name":"Las gu\u00edas de electrodos de los implantes cocleares MED-EL"}]},{"@type":"WebSite","@id":"https:\/\/blog.medel.pro\/de\/#website","url":"https:\/\/blog.medel.pro\/de\/","name":"MED-EL Professionals Blog","description":"","publisher":{"@id":"https:\/\/blog.medel.pro\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.medel.pro\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/blog.medel.pro\/de\/#organization","name":"MED-EL Professionals Blog","url":"https:\/\/blog.medel.pro\/de\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/blog.medel.pro\/de\/#\/schema\/logo\/image\/","url":"https:\/\/blog.medel.pro\/wp-content\/uploads\/2023\/05\/MED-EL_RGB_Red_Symbol.jpg","contentUrl":"https:\/\/blog.medel.pro\/wp-content\/uploads\/2023\/05\/MED-EL_RGB_Red_Symbol.jpg","width":200,"height":200,"caption":"MED-EL Professionals Blog"},"image":{"@id":"https:\/\/blog.medel.pro\/de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/medel"]},{"@type":"Person","@id":"https:\/\/blog.medel.pro\/de\/#\/schema\/person\/b81eab3e22287063f6f0d9e2499d0f02","name":"MED-EL"}]}},"_links":{"self":[{"href":"https:\/\/blog.medel.pro\/latam\/wp-json\/wp\/v2\/posts\/28693","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.medel.pro\/latam\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.medel.pro\/latam\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.medel.pro\/latam\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.medel.pro\/latam\/wp-json\/wp\/v2\/comments?post=28693"}],"version-history":[{"count":3,"href":"https:\/\/blog.medel.pro\/latam\/wp-json\/wp\/v2\/posts\/28693\/revisions"}],"predecessor-version":[{"id":29287,"href":"https:\/\/blog.medel.pro\/latam\/wp-json\/wp\/v2\/posts\/28693\/revisions\/29287"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.medel.pro\/latam\/wp-json\/wp\/v2\/media\/28056"}],"wp:attachment":[{"href":"https:\/\/blog.medel.pro\/latam\/wp-json\/wp\/v2\/media?parent=28693"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.medel.pro\/latam\/wp-json\/wp\/v2\/categories?post=28693"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.medel.pro\/latam\/wp-json\/wp\/v2\/tags?post=28693"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}